KORTING CAUSTIC RECOVERY UNIT Year 1986
A30 7912
Comprising :
Heat exchangers ,Pumps ,Control Valves,Evaporator ,Separator.
Weak Lye input / hour: .. about 3200 kg/hr. temp 50deg C . concentration 10.2 Be
Strong Lye output / hour: about 617 kg/h .temp 35deg C Concentration 40.Be
Steam consumption: 1260.Kg / hour 3.bar
Water consumption (cooling): 9-11 m3/h. inlet 20degC , outlet 70 deg C.
Water evaporation about 2583 kg/h